- General>
- Find your transmitter
Find your transmitter
Local configuration
Allows local configuration of spans, zero adjustment, setting thresholds and switch trigger algorithms, choosing units of measurements for displays, accessing function libraries. You can locally configure a device with controls on its housing or through the digital interface using special software and equipment (adapter, HART modem, communicator, computer, etc.).
Outdoor housing
A special version of housing that allows mounting the device outdoors and protects it from weather and mechanical damage. Most compact transmitters can have such housing as an option and it is the default option for Ex versions of transmitters. Pressure transmitters with outdoor housing can have an integrated display (LCD or LED, depending on the model).
Exia, Exd
Explosion-proof design: intrinsically safe circuit (Exia) and/or flameproof enclosure (Exd).
HART, Profibus, Modbus, Fieldbus
Transmitters capable of sending measurements data over one or several of the mentioned protocols.
Precision
The accuracy of precision pressure transmitters is ≤0.1% of span; they almost completely ignore temperature effect and allow configuration of parameters.
Flush diaphragm
Transmitters designed to measure pressure of viscous and pasty media; feature special design of the pressure port.
Hygienic/sanitary
Certified devices designed for food and medical factories, as well as other spheres that make use of "clean" technologies, like chemical laboratories. Special design implies a diaphragm seal; fill liquid (silicone oil, halocarbon, edible oil) and diaphragm material (stainless steel, tantalum, titanium) vary depending on the technology requirements. Some models can have special food-grade mechanical connections (clamp, hygienic union, etc.) and/or hygienic design of the housing.
SIL (Safety Integrity Level)
Transmitters complying to the requirements of IEC 61508/61511, international European safety standard (certified). The standard describes four Safety Integrity Levels (SIL); they are applied depending on the severity of the consequences that may occur if the system is not functioning properly. Thus, SIL determine the acceptable risk for the system. They reflect the likelihood of the system discharging its safety-related functions properly.
Marine version
Transmitters designed to be used as part of technological processes automatic control and regulation systems at offshore facilities (platforms, vessels, etc.). Heavy-duty housing of corrosion-resistant steel or special alloys allows measuring pressure of corrosive gases and liquids under extremely severe operating conditions. Marine versions of transmitters boast high resistance to pressure overload, vibration, shocks and peaks, reliably operate in a wide temperature range and have high long-term stability. The transmitters were certified by Germany's Germanischer Lloyd (GL), Norway's Det Norske Veritas (DNV), Russian Maritime Register. Please specify what certificates you need when ordering the transmitters.
DMP 331
Pressure transmitter for low and medium pressures- Pressure range from 0…0.04 to 0…40 bar; -1…0 bar
- Accuracy 0.5 / 0.35 / 0.25 / 0.2 % of span
- Output signal 0/4…20 mA; 0…10 V; 0…5 V; HART and other. (Ex-version optional)
DMP 330H
Low-cost pressure transmitter- Pressure range from 0..1 to 0..160 bar
- Accuracy 1.0% of span
- Output signal 4…20 mA, 0…10 V
DMP 330S
Multirange low-cost pressure transmitter- Pressure range from 0…1 to 0…600 bar; from -1…6 to -1…25 bar
- Accuracy 0,5 % of span
- Output signal 4…20 mA, 0.5…4.5 V
DMP 330M
Multirange low-cost pressure transmitter- Pressure range from 0…6 to 0…160 bar
- Accuracy 1.0 % of span
- Output signal 4…20 mA
DMP 330F
Multirange low-cost pressure transmitter- Pressure range from 0…1 to 0…400 bar
- Accuracy 0.5 % of span
- Output signal 4…20 mA
DMP 330L
Low-cost pressure transmitter- Pressure range from 0…1 to 0…400 bar
- Accuracy 0.5 % ofspan
- Output signal 4…20 mA, 0…10 V
DMP 343
Low pressure transmitter- Pressure range from 0…0.006 to 0…1 bar
- Accuracy 1.0 / 0.5 % of span
- Output signal 0/4…20 mA, 0…10 V, 0…5 V, HART (Ex-version optional)
DMP 333
Pressure transmitter for medium and high pressures- Pressure range from 0…60 to 0…600 bar
- Accuracy 0.35 / 0.25 / 0.2 % of span
- Output signal 0/4…20 mA, 0…10 V, 0…5 V, HART-protocol and other (Ex-version optional)
DMP 331i
Precision pressure transmitter with digital output- Pressure range from 0…0.4 to 0…40 bar
- Accuracy 0.1 % of span
- Output signal 4…20 mA (Ex-version optional), RS 485/HART, RS 485/Modbus, HART-protocol
DMP 331K
Precision pressure transmitter with 0.5 ms response time- Pressure range from 0…0.1 to 0…600 bar
- Accuracy 0.1 % of span
- Output signal 3-wire. 4…20 mA, 0.1…10 V
DMP 333i
Precision pressure transmitter with digital output- Pressure range from 0…60 to 0…600 bar
- Accuracy 0.1% of span
- Output signal 4…20 mA (Ex-version optional), RS 485/HART, RS 485/Modbus, HART-protocol
DMP 334
High pressure transmitter- Pressure range from 0…600 to 0…2200 bar
- Accuracy 0.35 % of span
- Output signal 0/4…20 mA, 0…10 V (Ex-version optional)
DMK 331
Pressure transmitter for aggressive media- Pressure range from 0…0.4 to 0…600 bar
- Accuracy 0.5 / 0.25 % of span
- Output signal 0/4…20 mA, 0…10 V, 0…5 V, HART and other. (Ex-version optional)
DPS 200
Pressure transmitter for non-aggressive gases- Pressure range from 0…0.006 to 0…1 bar
- Accuracy 2 % of span
- Output signal 0/4…20 mA, 0…10 V
DPS 300
Pressure transmitter for non-aggressive gases- Pressure range from 0…0.0016 to 0…1 bar
- Accuracy 1 % of span
- Output signal 3 wire 0…10 V, 0…20 mA (0…5 V, 4…20 mA select); 2 wire 4…20 mA
DPS+
Pressure transmitter with relay output- Pressure range from 0…0.006 to 0…1 bar
- Accuracy 2 / 1 / 0.35 % of span
- Output signal 0/4…20 mA, 0…10 V, 1 or 2 discrete outputs
DMD 341
Differential pressure transmitter- Pressure range from 0..0.0006 to 0..1 bar, differential
- Accuracy 0.35 / 1 / 2% of span
- Output signal 0 / 4..20 mA; 0 ... 10 V, 1 or 2 discrete outputs (PNP)
DMD 331
General purpose differential pressure transmitter- Pressure range from 0..0.2 to 0..16 bar
- Accuracy 0.5 / 1% of span
- Output signal 4..20 mA, 0 ... 10 V
DMP 331P
Sanitary pressure transmitter for food production / pharmaceuticals- Pressure range from 0...0.1 to 0...600 bar
- Accuracy 1 / 0.5 / 0.35 / 0.25% of span
- Output signal 0/4…20 mA, 0…10 V, 0…5 V, HART, Modbus
DMP 331Pi
Precision sanitary pressure transmitter for food production / pharmaceuticals- Pressure range from 0…0.4 to 0…40 bar
- Accuracy 0.1 % of span
- Output signal 0/4…20 mA, 0…10 V, 0…5 V
DMK 331P
Sanitary pressure transmitter for food production / pharmaceuticals- Pressure range from 0…1 to 0…400 bar
- Accuracy 0.5 / 0,25 % of span
- Output signal 0/4…20 mA, 0…10 V, 0…5 V, HART
DMD 831
Differential pressure transmitter with display- Pressure range from 0…0.8 to 0…70 bar
- Accuracy 2 % of span
- Output signal 4…20 mA
DS 200M
(BAROLI) Digital pressure gauge with indicator- Pressure range from 0 ...1,0 to 0 ... 600 bar
- Accuracy 0.5 / 0.25 % URL
- Sensor ceramic piezoresistive
DM 10
Digital pressure gauge- Pressure range from 0..1.6 bar to 0..250 bar
- Accuracy 1% of span
- Sensors ceramic, piezoresistive
x|act i
Precision pressure transmitter with display- Pressure range from 0…0.4 to 0…600 bar
- Accuracy 0.1 % of span
- Output signal 4…20 mA, HART
x|act ci
Precision pressure transmitter with display- Pressure range from 0…0.06 to 0…20 bar
- Accuracy 0,2 % of span
- Output signal 4…20 mA, HART
DMP 304
Extra high pressure transmitter- Pressure range from 0…2000 to 0…6000 bar
- Accuracy 0.5 / 0.25 % of span
- Output signal 4…20 mA, 0…10 V
DMK 456
Pressure transmitter for marine operating conditions- Pressure range from 0…0.04 bar to 0…20 bar
- Accuracy 0.35 / 0.25 / 0.20 % of span
- Output signal 4…20 mA, Ex version
DMP 457
Pressure transmitter for shipbbuilding- Pressure range from 0…0.1 to 0…600 bar
- Accuracy 0.5 / 0.35 / 0.25 % of span
- Output signal 4…20 mA
DMK 458
Pressure transmitter for shipbbuilding- Pressure range from 0…0.4 to 0…20 bar
- Accuracy 0.25 / 0.10 % of span
- Output signal 4…20 mA
HU 300
Hammer Union Pressure Transmitter- Pressure range from 0…345 to 0…1035 bar
- Accuracy 0.5 % of span
- Output signal 0/4…20 mA, 0…10 V, 0…5 V
DMD 331-A-S-LX/HX
Smart precision differential pressure/level transmitter with HART-protocol- Pressure range up to 250 bar
- Accuracy 0.075 / 0.04 % of span
- Output signal 4…20 mA (option 0…20 mA), HART-protocol
HMP 331
Precision smart pressure transmitter- Pressure range from 0…0.4 to 0…600 bar; -1…0 bar
- Accuracy 0.1 % of span
- Output signal 4…20 mA, HART
HMP 331-A-S
Precision smart gauge pressure transmitter with HART-protocol- Pressure range from 0…0.0125 to 0…250 bar; -1…0 bar
- Accuracy 0.075 % of span
- Output signal 4…20 mA, HART
DS 200
Multi-function Pressure Transmitter/Switch with Indicator- Pressure range from 0…0.04 to 0…600 bar
- Accuracy 0.5 / 0.35 / 0.25 % of span
- Output signal 4…20 mA, 0…10 V (optional Ex version), 1 or 2 programmable digital outputs
DS 200P
Multi-function Pressure Transmitter- Pressure range from 0…0.1 to 0…40 bar
- Accuracy 0.5 / 0.35 / 0.25 % of span
- Output signal 4…20 mA, 0…10 V (optional Ex version), 1 or 2 programmable digital outputs
DS 201
Multi-function Pressure Transmitter/Switch with Indicator- Pressure range from 0…0.06 to 0…600 bar
- Accuracy 0.5 % of span
- Output signal 4…20 mA / 2-wire, 0…10 V / 3-wire
DS 4
Switch Output Pressure Transmitter- Pressure range from 0..1 to 0..10 bar
- Accuracy 1.0 % of span
- Output signal 1 or 2 discrete outputs (PNP) + proportional 0…5 V
DS 6
Programmable Pressure Switch for Hydraulic Systems- Pressure range 0..2 to 0..400 bar
- Accuracy 1 % of span
- Output signal 1 or 2 discrete outputs (PNP)
LMP 331i
Precision Hydrostatic Pressure Transmitter with Digital Output- Pressure range from 0 ... 1 mWC to 0 ... 400 mWC
- Accuracy 0.1 % os span
- Output signal 4…20 mA (optional Ex version), zero and range adjustment via RS232, RS 485/HART, RS 485/Modbus, HART protocol
LMK 331
Gauge Pressure Level Transmitter for Process Lines and Vessels- Pressure range from 0 ... 6 mWC to 0...600 mWC
- Accuracy 1.0 / 0.5 % of span
- Output signal 4…20 mA, 0…10 V, HART protocol (optional Ex version)
LMK 351
Gauge Pressure Level Transmitter for Process Lines and Vessels- Pressure range from 0 ... 0,4 mWC to 0 ... 100 mWC
- Accuracy 0.35 / 0.25 % of span
- Ouput signal 4…20 mA (optional Ex version)
LMP 305
Stainless Steel Liquid Level Transmitter- Pressure range from 0 ... 1 mWC to 0...250 mWC
- Accuracy 0.5 / 0,35 / 0.25 % of span
- Output signal 4…20 mA
LMP 307
Stainless Steel Liquid Level Transmitter- Pressure range from 0…1 to 0…250 mWC
- Accuracy 0.5 / 0.35 / 0.25 % of span
- Output signal 0/4…20 mA, 0…10 V, HART protocol (optional Ex version)
LMP 307i
Precision Submersible Level Transmitter- Pressure range from 0 ... 4 mWC to 0 ... 200 mWC
- Accuracy 0.1 % of span
- Output signal 0/4…20 mA, 0…10 V, HART protocol (optional Ex version)
LMP 308
Stainless Steel Level Transmitter- Pressure range from 0 ... 1 mWC to 0 ... 250 mWC
- Accuracy 0.5 / 0.35 / 0.25 % of span
- Output signal 0/4…20 mA, 0…10 V (optional Ex version)
LMP 308i
Stainless Steel Smart Submersible Level Transmitter- Pressure range from 0 ... 0.4 mWC to 0 ... 200 mWC
- Accuracy 0.1 % of span
- Output signal 4…20 mA (optional Ex version), configuration via RS232
LMP 808
Submersible Liquid Level Transmitter (PVC Housing)- Pressure range from 0 ... 0.4 mWC to 0 ... 100 mWC
- Accuracy 0.5 / 0.35 / 0.25 / 0.1 % of span
- Output signal 4…20 mA, 0…10 V
LMK 306
Submersible ultra-small probe with ceramic diaphragm- Pressure range from 0 ... 6 mWC up to 0 ... 200 mWC
- Accuracy 0.5 % of span
- Output signal 4…20 mA/ 2-wire
LMK 307
Submersible probe with ceramic diaphragm- Pressure range from 0 ... 4 mWC to 0 ... 250 mWC
- Accuracy 0.5 % of span
- Output signal 0/4…20 mA, 0…10 V
LMK 358
Ceramic Sensor Submersible Level Transmitter- Pressure range from 0…0.4 mWC up to 0…100 mWC
- Accuracy 0.35 / 0.25 % of span
- Output signal 0/4…20 mA (optional Ex version)
LMK 358H
Precision Submersible Level Transmitter with HART protocol- Pressure range from 0…0.6 mWC up to 0…100 mWC
- Accuracy 0.2 % of span
- Output signal 4…20 mA (optional Ex version), HART protocol
LMK 458
Marine Submersible Level Transmitter- Pressure range from 0…0.4 of water up to 0…200 mWC
- Accuracy 0.25 / 0.1 % of span
- Output signal 4…20 mA
LMK 858
Aggressive Media Submersible Level Transmitter- Pressure range from 0…0.4 mWC up to 0…100 mWC
- Accuracy 0.35 / 0.25 % of span
- Output signal 4…20 mA
DMP 331i
Precision pressure transmitter with digital output- Pressure range from 0…0.4 to 0…40 bar
- Accuracy 0.1 % of span
- Output signal 4…20 mA (Ex-version optional), RS 485/HART, RS 485/Modbus, HART-protocol
DMP 331K
Precision pressure transmitter with 0.5 ms response time- Pressure range from 0…0.1 to 0…600 bar
- Accuracy 0.1 % of span
- Output signal 3-wire. 4…20 mA, 0.1…10 V
DMP 333i
Precision pressure transmitter with digital output- Pressure range from 0…60 to 0…600 bar
- Accuracy 0.1% of span
- Output signal 4…20 mA (Ex-version optional), RS 485/HART, RS 485/Modbus, HART-protocol
DMP 331Pi
Precision sanitary pressure transmitter for food production / pharmaceuticals- Pressure range from 0…0.4 to 0…40 bar
- Accuracy 0.1 % of span
- Output signal 0/4…20 mA, 0…10 V, 0…5 V
DMK 458
Pressure transmitter for shipbbuilding- Pressure range from 0…0.4 to 0…20 bar
- Accuracy 0.25 / 0.10 % of span
- Output signal 4…20 mA
DMD 331-A-S-LX/HX
Smart precision differential pressure/level transmitter with HART-protocol- Pressure range up to 250 bar
- Accuracy 0.075 / 0.04 % of span
- Output signal 4…20 mA (option 0…20 mA), HART-protocol
HMP 331
Precision smart pressure transmitter- Pressure range from 0…0.4 to 0…600 bar; -1…0 bar
- Accuracy 0.1 % of span
- Output signal 4…20 mA, HART
HMP 331-A-S
Precision smart gauge pressure transmitter with HART-protocol- Pressure range from 0…0.0125 to 0…250 bar; -1…0 bar
- Accuracy 0.075 % of span
- Output signal 4…20 mA, HART
LMP 331i
Precision Hydrostatic Pressure Transmitter with Digital Output- Pressure range from 0 ... 1 mWC to 0 ... 400 mWC
- Accuracy 0.1 % os span
- Output signal 4…20 mA (optional Ex version), zero and range adjustment via RS232, RS 485/HART, RS 485/Modbus, HART protocol
LMP 307i
Precision Submersible Level Transmitter- Pressure range from 0 ... 4 mWC to 0 ... 200 mWC
- Accuracy 0.1 % of span
- Output signal 0/4…20 mA, 0…10 V, HART protocol (optional Ex version)
LMP 308i
Stainless Steel Smart Submersible Level Transmitter- Pressure range from 0 ... 0.4 mWC to 0 ... 200 mWC
- Accuracy 0.1 % of span
- Output signal 4…20 mA (optional Ex version), configuration via RS232
LMP 808
Submersible Liquid Level Transmitter (PVC Housing)- Pressure range from 0 ... 0.4 mWC to 0 ... 100 mWC
- Accuracy 0.5 / 0.35 / 0.25 / 0.1 % of span
- Output signal 4…20 mA, 0…10 V
LMK 458
Marine Submersible Level Transmitter- Pressure range from 0…0.4 of water up to 0…200 mWC
- Accuracy 0.25 / 0.1 % of span
- Output signal 4…20 mA
DMP 331
Pressure transmitter for low and medium pressures- Pressure range from 0…0.04 to 0…40 bar; -1…0 bar
- Accuracy 0.5 / 0.35 / 0.25 / 0.2 % of span
- Output signal 0/4…20 mA; 0…10 V; 0…5 V; HART and other. (Ex-version optional)
DMP 330H
Low-cost pressure transmitter- Pressure range from 0..1 to 0..160 bar
- Accuracy 1.0% of span
- Output signal 4…20 mA, 0…10 V
DMP 330S
Multirange low-cost pressure transmitter- Pressure range from 0…1 to 0…600 bar; from -1…6 to -1…25 bar
- Accuracy 0,5 % of span
- Output signal 4…20 mA, 0.5…4.5 V
DMP 330M
Multirange low-cost pressure transmitter- Pressure range from 0…6 to 0…160 bar
- Accuracy 1.0 % of span
- Output signal 4…20 mA
DMP 330F
Multirange low-cost pressure transmitter- Pressure range from 0…1 to 0…400 bar
- Accuracy 0.5 % of span
- Output signal 4…20 mA
DMP 330L
Low-cost pressure transmitter- Pressure range from 0…1 to 0…400 bar
- Accuracy 0.5 % ofspan
- Output signal 4…20 mA, 0…10 V
DMP 343
Low pressure transmitter- Pressure range from 0…0.006 to 0…1 bar
- Accuracy 1.0 / 0.5 % of span
- Output signal 0/4…20 mA, 0…10 V, 0…5 V, HART (Ex-version optional)
DMP 333
Pressure transmitter for medium and high pressures- Pressure range from 0…60 to 0…600 bar
- Accuracy 0.35 / 0.25 / 0.2 % of span
- Output signal 0/4…20 mA, 0…10 V, 0…5 V, HART-protocol and other (Ex-version optional)
DMP 334
High pressure transmitter- Pressure range from 0…600 to 0…2200 bar
- Accuracy 0.35 % of span
- Output signal 0/4…20 mA, 0…10 V (Ex-version optional)
DMK 331
Pressure transmitter for aggressive media- Pressure range from 0…0.4 to 0…600 bar
- Accuracy 0.5 / 0.25 % of span
- Output signal 0/4…20 mA, 0…10 V, 0…5 V, HART and other. (Ex-version optional)
DPS 200
Pressure transmitter for non-aggressive gases- Pressure range from 0…0.006 to 0…1 bar
- Accuracy 2 % of span
- Output signal 0/4…20 mA, 0…10 V
DPS 300
Pressure transmitter for non-aggressive gases- Pressure range from 0…0.0016 to 0…1 bar
- Accuracy 1 % of span
- Output signal 3 wire 0…10 V, 0…20 mA (0…5 V, 4…20 mA select); 2 wire 4…20 mA
DPS+
Pressure transmitter with relay output- Pressure range from 0…0.006 to 0…1 bar
- Accuracy 2 / 1 / 0.35 % of span
- Output signal 0/4…20 mA, 0…10 V, 1 or 2 discrete outputs
DMD 341
Differential pressure transmitter- Pressure range from 0..0.0006 to 0..1 bar, differential
- Accuracy 0.35 / 1 / 2% of span
- Output signal 0 / 4..20 mA; 0 ... 10 V, 1 or 2 discrete outputs (PNP)
DMD 331
General purpose differential pressure transmitter- Pressure range from 0..0.2 to 0..16 bar
- Accuracy 0.5 / 1% of span
- Output signal 4..20 mA, 0 ... 10 V
DMP 331P
Sanitary pressure transmitter for food production / pharmaceuticals- Pressure range from 0...0.1 to 0...600 bar
- Accuracy 1 / 0.5 / 0.35 / 0.25% of span
- Output signal 0/4…20 mA, 0…10 V, 0…5 V, HART, Modbus
DMK 331P
Sanitary pressure transmitter for food production / pharmaceuticals- Pressure range from 0…1 to 0…400 bar
- Accuracy 0.5 / 0,25 % of span
- Output signal 0/4…20 mA, 0…10 V, 0…5 V, HART
DMD 831
Differential pressure transmitter with display- Pressure range from 0…0.8 to 0…70 bar
- Accuracy 2 % of span
- Output signal 4…20 mA
DS 200M
(BAROLI) Digital pressure gauge with indicator- Pressure range from 0 ...1,0 to 0 ... 600 bar
- Accuracy 0.5 / 0.25 % URL
- Sensor ceramic piezoresistive
DM 10
Digital pressure gauge- Pressure range from 0..1.6 bar to 0..250 bar
- Accuracy 1% of span
- Sensors ceramic, piezoresistive
x|act i
Precision pressure transmitter with display- Pressure range from 0…0.4 to 0…600 bar
- Accuracy 0.1 % of span
- Output signal 4…20 mA, HART
x|act ci
Precision pressure transmitter with display- Pressure range from 0…0.06 to 0…20 bar
- Accuracy 0,2 % of span
- Output signal 4…20 mA, HART
DMP 304
Extra high pressure transmitter- Pressure range from 0…2000 to 0…6000 bar
- Accuracy 0.5 / 0.25 % of span
- Output signal 4…20 mA, 0…10 V
DMK 456
Pressure transmitter for marine operating conditions- Pressure range from 0…0.04 bar to 0…20 bar
- Accuracy 0.35 / 0.25 / 0.20 % of span
- Output signal 4…20 mA, Ex version
DMP 457
Pressure transmitter for shipbbuilding- Pressure range from 0…0.1 to 0…600 bar
- Accuracy 0.5 / 0.35 / 0.25 % of span
- Output signal 4…20 mA
HU 300
Hammer Union Pressure Transmitter- Pressure range from 0…345 to 0…1035 bar
- Accuracy 0.5 % of span
- Output signal 0/4…20 mA, 0…10 V, 0…5 V
DS 200
Multi-function Pressure Transmitter/Switch with Indicator- Pressure range from 0…0.04 to 0…600 bar
- Accuracy 0.5 / 0.35 / 0.25 % of span
- Output signal 4…20 mA, 0…10 V (optional Ex version), 1 or 2 programmable digital outputs
DS 200P
Multi-function Pressure Transmitter- Pressure range from 0…0.1 to 0…40 bar
- Accuracy 0.5 / 0.35 / 0.25 % of span
- Output signal 4…20 mA, 0…10 V (optional Ex version), 1 or 2 programmable digital outputs
DS 201
Multi-function Pressure Transmitter/Switch with Indicator- Pressure range from 0…0.06 to 0…600 bar
- Accuracy 0.5 % of span
- Output signal 4…20 mA / 2-wire, 0…10 V / 3-wire
DS 4
Switch Output Pressure Transmitter- Pressure range from 0..1 to 0..10 bar
- Accuracy 1.0 % of span
- Output signal 1 or 2 discrete outputs (PNP) + proportional 0…5 V
DS 6
Programmable Pressure Switch for Hydraulic Systems- Pressure range 0..2 to 0..400 bar
- Accuracy 1 % of span
- Output signal 1 or 2 discrete outputs (PNP)
LMK 331
Gauge Pressure Level Transmitter for Process Lines and Vessels- Pressure range from 0 ... 6 mWC to 0...600 mWC
- Accuracy 1.0 / 0.5 % of span
- Output signal 4…20 mA, 0…10 V, HART protocol (optional Ex version)
LMK 351
Gauge Pressure Level Transmitter for Process Lines and Vessels- Pressure range from 0 ... 0,4 mWC to 0 ... 100 mWC
- Accuracy 0.35 / 0.25 % of span
- Ouput signal 4…20 mA (optional Ex version)
LMP 305
Stainless Steel Liquid Level Transmitter- Pressure range from 0 ... 1 mWC to 0...250 mWC
- Accuracy 0.5 / 0,35 / 0.25 % of span
- Output signal 4…20 mA
LMP 307
Stainless Steel Liquid Level Transmitter- Pressure range from 0…1 to 0…250 mWC
- Accuracy 0.5 / 0.35 / 0.25 % of span
- Output signal 0/4…20 mA, 0…10 V, HART protocol (optional Ex version)
LMP 308
Stainless Steel Level Transmitter- Pressure range from 0 ... 1 mWC to 0 ... 250 mWC
- Accuracy 0.5 / 0.35 / 0.25 % of span
- Output signal 0/4…20 mA, 0…10 V (optional Ex version)
LMK 306
Submersible ultra-small probe with ceramic diaphragm- Pressure range from 0 ... 6 mWC up to 0 ... 200 mWC
- Accuracy 0.5 % of span
- Output signal 4…20 mA/ 2-wire
LMK 307
Submersible probe with ceramic diaphragm- Pressure range from 0 ... 4 mWC to 0 ... 250 mWC
- Accuracy 0.5 % of span
- Output signal 0/4…20 mA, 0…10 V
LMK 358
Ceramic Sensor Submersible Level Transmitter- Pressure range from 0…0.4 mWC up to 0…100 mWC
- Accuracy 0.35 / 0.25 % of span
- Output signal 0/4…20 mA (optional Ex version)
LMK 358H
Precision Submersible Level Transmitter with HART protocol- Pressure range from 0…0.6 mWC up to 0…100 mWC
- Accuracy 0.2 % of span
- Output signal 4…20 mA (optional Ex version), HART protocol
LMK 858
Aggressive Media Submersible Level Transmitter- Pressure range from 0…0.4 mWC up to 0…100 mWC
- Accuracy 0.35 / 0.25 % of span
- Output signal 4…20 mA